> For the complete documentation index, see [llms.txt](https://docs.platform9.com/llms.txt). Markdown versions of documentation pages are available by appending `.md` to page URLs; this page is available as [Markdown](https://docs.platform9.com/private-cloud-director/integrations/cohesity-dataprotect-with-pcd.md).

# Cohesity DataProtect with PCD

Configure Cohesity DataProtect as the NFS backup repository for Storware-protected VMs running in Private Cloud Director.

Cohesity DataProtect provides a secure, policy-driven backup repository for virtual machines running in Private Cloud Director (PCD).

Storware manages the OpenStack-aware backup and recovery workflow. It writes backup data to a Cohesity SmartFiles NFS 4.1 View. Cohesity provides immutability, retention, deduplication, compression, encryption, quotas, and fault tolerance.

Cohesity lists Private Cloud Director as a supported OpenStack distribution. Confirm the version pairing on the [Cohesity supported versions page](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/ReleaseNotes/SupportedVersions.htm#OpenStack).

### How it works

![](https://191062915-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FahFslWhNYrhniOMicRJ1%2Fuploads%2FOpLgSKgm2PBvH0YKGGCN%2FPlatform9-Cohesity.png?alt=media\&token=c20d02ca-63f4-405a-b54f-df2840432490)

Three components work together:

* **Private Cloud Director** hosts the protected virtual machines.
* **Storware** discovers VMs, schedules backups, creates snapshots, and transfers data.
* **Cohesity DataProtect** provides the SmartFiles NFS 4.1 View that stores backup data.

During a backup, Storware snapshots VM data in PCD. It then writes the data to the mounted Cohesity NFS View. See the Cohesity [backup architecture](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/backup-openstack.htm#BackupArchitecture) for details.

### Prerequisites

Before you begin, ensure your environment meets these requirements.

#### Private Cloud Director and Storware

* PCD version **2025.10-180** or later.
* Storware Backup and Recovery version **7.5** or later.
* Administrator access to the PCD tenants you plan to protect.
* A deployed Storware integration. Follow [Storware Integration with PCD](/private-cloud-director/integrations/storware-integration-with-pcd.md) to deploy and connect Storware.

{% hint style="info" %}
If you have a Cohesity-provided Storware license, download the "OpenStack Software Backup and Recovery" package from [Cohesity downloads](https://downloads.cohesity.com/downloads) page for your Storware deployment.
{% endhint %}

#### Cohesity DataProtect

* DataProtect version **7.4.1** and a healthy Cohesity cluster with a Storage Domain.
* An account with permission to create and manage views.
* The required environment inputs and validations. See [Plan and Prepare for OpenStack VMs Protection](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/planprepare-openstack.htm#PlanandPrepareforOpenStackVMsProtection).

#### Network requirements

Allow bidirectional traffic between the Storware nodes and the Cohesity cluster. See [Validate Network Requirements](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/planprepare-openstack.htm#ValidateNetworkRequirements).

* **TCP 2049**: NFSv4.1 backup and restore data transfer.

### Set up the backup repository

A Cohesity View is a storage location that provides NFS, SMB, S3, or SWIFT access for storing files, backups, snapshots, and VM data.

Authorized systems can mount a view. A view can also act as a datastore for VM cloning and recovery.

#### Create and secure the Cohesity View

Create the storage location on the Cohesity cluster.

1. In Cohesity DataProtect, go to **SmartFiles** → **Views** → **Create View**.
2. Configure the following settings:
   * **Category**: Backup Target
   * **Type**: General Backup
   * **Read/Write Protocol**: NFS 4.1
   * **Performance Policy**: Backup Target High
3. Apply a subnet allowlist. Allow access only from Storware node subnets.
4. Set **NFS Squash** to **None** for the Storware subnet.
5. Optionally, set a Logical Quota and alert threshold.

{% hint style="warning" %}
NFS squash removes required write permissions. Backups fail with `permission denied` errors when it remains enabled.
{% endhint %}

For detailed view-creation steps, see [Cohesity Backup Target Setup](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/backup-openstack.htm#CohesityBackupTargetSetup).

#### Connect Storware and run the first backup

Next, configure Storware to use the NFS view you just created as its primary backup destination.

1. Mount the Cohesity View on the Storware node. See the [reference mount command](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/backup-openstack.htm#ReferenceMountCommand).
2. Ensure the mount directory is owned by the Storware user, usually `vprotect`.
3. In Storware, create a **File System** backup destination.
4. Enter the mounted Cohesity View path as the destination.
5. Create a backup policy for your PCD instances.
6. Select the Cohesity View as the policy's primary backup destination.

For Storware-side policy guidance, see [Configure Backup in Storware](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/backup-openstack.htm#ConfigureBackupinStorware).

#### Verify the first backup

Back up one small VM, then confirm the data reached Cohesity.

Open the view in **SmartFiles** → **Views**. Confirm its logical and physical usage are no longer zero.

<figure><img src="https://191062915-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FahFslWhNYrhniOMicRJ1%2Fuploads%2FpTN9pB3MWXWHkfceFuLe%2FScreenshot%202026-09-24%20at%2016-49-42%20Cohesity%20Dashboard.png?alt=media&amp;token=58505bef-9dd6-4781-a56a-b0664f2935c2" alt="Cohesity SmartFiles interface showing 1.5GB usage"><figcaption></figcaption></figure>

#### Cohesity View features

Cohesity Views expose features for several protocols. The following features apply to an NFS Backup Target View used by Storware.

| Feature                                                                                                                                                | Support                         | How to use it                                                                                                                                    |
| ------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------ |
| [IP allowlists](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/ViewsSpecifyWhitelistedSubnets.htm#AddSubnetstoAllowlists) | Supported and recommended       | Use global or view-level subnet allowlists. Allow only Storware node subnets that require read and write access.                                 |
| [NFS squash](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/nfs-squash.htm)                                               | Supported                       | Root squash and all squash can be configured at the subnet, netgroup, or view level; subnet/netgroup settings supersede view-level settings      |
| [NFS root permissions](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#NFSOptions)                        | Supported                       | The cluster administrator can set UID/GID for the root of the Cohesity view                                                                      |
| [Logical quota](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/ViewQuotas.htm#UserandDirectoryQuotasforViews)             | Supported                       | A view can inherit quota settings or override them with a Logical Quota and alert threshold                                                      |
| [User quotas](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/ViewQuotas.htm#UserandDirectoryQuotasforViews)               | Supported                       | User quotas are supported on views                                                                                                               |
| [Directory quotas](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/ViewQuotas.htm#UserandDirectoryQuotasforViews)          | Supported                       | Directory quotas are supported on views                                                                                                          |
| [QoS policy](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Concepts/QoS.htm#QoSPoliciesforCohesityViews)                                    | Recommended: Backup Target High | Create the view with **Backup Target** → **General Backup** → **NFS 4.1** → **Backup Target High**.                                              |
| [Protect the view](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#Protection)                            | Supported                       | Views can be protected with snapshots/backup-related capabilities; use this if you need repository-side protection workflows                     |
| [Snapshot Self-Service](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#SnapshotSelfService)              | Supported                       | NFS snapshot self-service can be enabled by turning on the snapshot directory option for the view                                                |
| [Antivirus scanning](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#Antivirus)                           | Supported                       | Antivirus scanning can be enabled on a view if an antivirus provider is registered on the cluster                                                |
| [File Services audit logs](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#AuditLogs)                     | Supported                       | Audit logging can be enabled on views; NFS view operations such as create, delete, rename, ownership change, and content modification are logged |
| [Discoverable Shares](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#AuditLogs)                          | Supported                       | NFS shares are not discoverable by default; if enabled, they appear in showmount output                                                          |
| [Pin View to SSD](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/pin-views.htm#PinViewstoSSD)                             | Conditionally supported         | View pinning is supported only with Test And Dev High or Backup Target SSD QoS policies                                                          |
| [File DataLock](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#File)                                     | Supported                       | File DataLock can be enabled                                                                                                                     |
| [File extension filtering](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Dashboard/Platform/view-options.htm#FileFiltering)                 | Supported                       | Views support allowed file type filtering                                                                                                        |

#### Known behaviors and limitations

* **File size limits**: Files larger than 1 TB can occasionally fail over NFSv4.1. Consider this for exceptionally large VMs.
* **Virtual Edition storage ratio**: The metadata tier limits data-tier capacity to a 16:1 ratio.
* **Space reclamation**: Deleted backup space can take up to 24 hours to appear in capacity tools.
* For more details, see [Considerations](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/planprepare-openstack.htm).

### References

* [Cohesity 7.4.1 User Guide](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/Welcome/Welcome.htm)
* [Cohesity 7.4.1 OpenStack Introduction](https://docs.cohesity.com/docs/dataprotect/7.4.1/Content/OpenStack/openstack-introduction.htm)
* [Storware Integration with PCD](/private-cloud-director/integrations/storware-integration-with-pcd.md)


---

# Agent Instructions
This documentation is published with GitBook. GitBook is the documentation platform designed so that both humans and AI agents can read, navigate, and reason over technical content effectively. Learn more at gitbook.com.

## Querying This Documentation
If you need additional information that is not directly available in this page, you can query the documentation by asking a question.

Perform an HTTP GET request on the following URL with the `ask` and `goal` query parameters:

```
GET https://docs.platform9.com/private-cloud-director/integrations/cohesity-dataprotect-with-pcd.md?ask=<question>&goal=<user_goal>
```

`ask` is the immediate question: it should be specific, self-contained, and written in natural language.
`goal` is what the user is ultimately trying to achieve, the reason they need the answer. Sharing it helps GitBook give you a better, more relevant answer. A goal is most helpful when it describes the outcome the user wants rather than restating the question. For example, with `ask=how do I create an API token`, a goal like `automate deployments from our CI pipeline` lets GitBook tailor the answer to that use case.

The response will contain a direct answer to the question and relevant excerpts and sources from the documentation.

Use this mechanism when the answer is not explicitly present in the current page, you need clarification or additional context, or you want to retrieve related documentation sections.